The gas cylinder band is an ideal way of eliminating wastage
of gas. It is an electrical resistance fitted with a thermostat
which under adverse weather conditions (low temperatures)
keeps the gas pressure constant and also allows the cylinder
to be used until completely empty.
INSTRUCTIONS FOR USE
1 - Make sure that the outer surface of the cylinder is
free from rust, dust and other deposits.
2 - Position the band around the cylinder with the joint
above the welded seam.
3 - Hold in position using the central fastener and regulate
the fit around the cylinder then close the other 2 fasteners.
4 - The cable should preferably be placed towards the bottom
(see drawing).
5 - To avoid damaging the electrical cable it is advisable
to fasten the cable to the cylinder using electricians straps
or similar.
6 - Switch on 4 to 5 minutes to pre-heat before using the
gas.
7 - If the cylinder is not being used for several hours,
unplug the unit.
DAMAGE RISKS TO THE BAND
a - The band must not be bent to less than R° 10.
b - The cable attached to the band must not be subjected
to being pulled at more than 8 to 10 Kg.
c - The band must not have any weight or sharp objects placed
on the heater area.
d - Store in a dry place.
PROPER STORAGE
After use, the band and all of its component parts should
be rolled up to a diameter of 15÷20 cm. in its original
box.
TECHNICAL DATA SHEET N. 5
- Flexible laminate heater element 230 Volts 400 and/or
700 Watt, maximum working temperature 175°C, tested
to EN 60335-1 (except paragraph 30).
- EU Certificate (European Standard EN 55014-1 A1, 61000-3-2,
61000-3-3).
- Insulated with vulcanised silicone rubber.
- Glass fabric covering on the outer surface.
- Working thermostat 70°C, 100.000 cycles.
- 2 phase electric cable with vulcanised silicone rubber
insulation diam. 7 mm., 1500 mm. long.
- 6 metal clips 8,7x8,5 mm.
- 3 silicone elastic straps 24x87 mm.
- 16A - 6h plug 200+250 volt.
- Dimensions: lenght 1.000x135 mm. art. 119.2.
- Dimensions: lenght 1.130x200 mm. art. 119.3.
- Dimensions: lenght 950x135 mm. art. 119.4.
- Dimensions: lenght 930x145 mm. art. 119.5.