LAYING TECHNOLOGY
From Art. 113.1 to 114.3
Install the waterproofing cap sheet. Prepare the
pipe adapter by cutting the step at the appropriate
diameter. Place the adapter over the pipe and
weld the flange to the waterproofing membrane
using a hot air gun.
SPECIFICATION
Supply and install ITALPROFILI pipe adapter for
PVC - TPO and PPpolyolefin suitable for fitting
to pipe diameters 34-60-75-80-90-100-110-115-125,
having a round flexible flange. Hose clips must
be instainless steel.
BELLOWS ADAPTER from Art. 58 to 59.2
Install the waterproofing cap sheet. Prepare the
bellows adapter bycutting the step at the appropriate
diameter to suit the pipe. Place over
the pipe and weld the flange to the waterproofing
membrane. Cut thevent pipe at 31 cm. from the
roof deck level and fit suitable diameter anticondensation
aereator.
SPECIFICATION
Supply and install ITALPROFILI anticondensation
aereator forbathrooms, kitchens etc. for pipe
diameters 80 mm. h 270 mm.,diameter 100 mm. h
305 mm. diameter 125 mm. h 350 mm. complete
with base and fitting for dealing to the waterproofing
membrane.